| Prooduct Name |
High Wind Speed Rain Test Chamber |
| Prooduct Model |
HWR3600 |
| Technical Parameters |
Product Attributes |
Working chamber dimensions(mm) |
1500×1600×1500(W×H×D) |
| External dimensions(mm) |
4200×7520×2405(W×H×D) |
| Rain Test |
Rainfall Intensity |
10~20 cm/h(The rainfall amount and rainfall intensity at the turntable can be adjusted.) |
| Raindrop Diameter |
0.5mm~4.5mm |
| Wind Speed Range |
5~18m/s(The horizontal wind speed at the center of the turntable air inlet and the raindrop angle shall be in accordance with the actual blowing conditions.) |
| Rain Test Time |
It can be freely set within 0-999 minutes, automatically controlled, and can cycle periodically. |
| Heating Range of Test Specimens |
The water temperature of rain is +10°C (up to +55°C). |
| Rotary Worktable |
Dimensions: Φ800mm, and the rotation speed of the turntable can be adjusted. |
|
Load-bearing:≥65kg |
| Workpiece Size Limitation |
The maximum allowable size of the test piece is:Φ700mm×H700mm |
| Dripping Rain Test |
Heating Range of Test Specimens |
The water temperature of rain is +10°C (up to +55°C). |
| Drip Pan Area |
760×760mm,The height of the drip pan can be adjusted. |
| Raindrop Diameter |
0.5mm~4.5mm,Aperture Spacing 25.4mm |
| Water Drip Volume |
≥280±30L /㎡·h |
| Rain Dripping Distance |
≥5 meters (to meet the raindrop velocity requirement of ≥9 m/s) |
| Water Supply |
The water pump supplies water continuously, and the water level of the drip pan is controlled. |
| Rain Dripping Time |
0~999min,Adjustable Configuration |
| Workpiece Size Limitation |
The maximum allowable size of the test piece is:Φ700mm×H700mm |
| Waterproof Test |
Flushing Pressure |
≥276kPa |
| Heating Range of Test Specimens |
The water temperature of rain is +10°C (up to +55°C). |
| Nozzle |
Stainless steel material, grid-type top layout, with adjustable nozzle angles; a movable nozzle is arranged on the side. |
| Number of Nozzles |
Within each 0.56 square meters of the surface area receiving rain, at least one nozzle shall be installed 450mm to 500mm away from the surface of the test specimen. |
| Water Supply Mode |
The water pump supplies water continuously |
| Test Time |
0~999min,Adjustable Configuration |
| Raindrop Diameter |
2mm~4.5mm |
| Workpiece Size Limitation |
The maximum allowable size of the test piece is:Φ700mm×H700mm |